Metal-Insert Male Threaded Tee
Download product sheet (PDF)Creates a male-threaded branch on a PE line. Check the centre outlet thread independently of the main pipe diameter.
Available for bulk orders. Include the product code, size, quantity and delivery destination in your enquiry.
Request a Bulk-Order Quote
Ertunç Plastik · Bulk OrdersDimensions and product codes
Pipe connection dimensions are in mm; thread sizes marked with a double quote are in inches.
Pieces per bag reflects the catalogue packing quantity, not a minimum order quantity. Confirm your order quantity and packing format when requesting a quote.
Application and Product Selection
A male-threaded tee branches a PE main to a female-threaded valve or component. Specify the main pipe size and male branch thread separately, and check the outlet direction against the layout.
Select from the Metal-Insert Compression Fittings dimensions in this page’s product-code table. Do not assume another series offers the same size range.
Define the connection before ordering
- Reading the size
- Record the pipe diameter and nominal thread size separately. An inch-designated thread size is not a measured pipe bore.
- Matching and layout
- The male-threaded end connects to a compatible female-threaded part. For an elbow or tee, also show the position of the threaded outlet on the order sketch.
- An example from the catalogue
- Product code: KDT2020012020 · Size: 20x1/2"x20
This example identifies one catalogue row; use the code for your required size and state the quantity in your enquiry.
Assembly and Installation Planning
Leave sufficient space to assemble the mating part on the threaded outlet. Avoid lateral loading on the body and verify that the sealing material is suitable for the connection.
Bulk Orders and Quotation Details
Ertunç Plastik accepts bulk-order enquiries. Send the product code, size, quantity and delivery destination together.
Send main-run sizes, male branch thread and the quantity list.
Stock, packaging, delivery and commercial terms are confirmed in the written quotation. For mixed sizes, list each code on a separate line.
Metal-Insert Male Threaded Tee: application and model selection
A male-threaded tee branches a PE main to a female-threaded valve or component.
Where an irrigation main needs a branch, describe all three connections in a sketch or order line. An equal compression tee, a reducing tee and a threaded branch are separate model choices. Assess the middle outlet's direction and connection form separately from the continuation of the main.
Read the catalogue size and series context
Check each main-line and branch connection separately. Do not fill a missing third-end size by guessing from the catalogue size order. Actual catalogue records for this model include 20×1/2"×20, 40×1 1/4"×40, 63×2"×63. Read the complete size expression alongside the series identity; do not transfer the size range of another similarly named model to this one.
Product code, packaging and piece quotation
Use “the selected row's product code / the selected catalogue size” and requested pieces on each quotation line. Catalogue pack quantity is separate from requested quantity or minimum order. Confirm current piece price, stock, packaging and delivery in writing.
What should be confirmed before installation?
Confirm the conveyed fluid, temperature, operating and surge pressure, pipe or hose class and connection form against information for the selected product. A series name, appearance or another component's data does not establish suitability of the whole installation. Use the relevant instructions for tightening and sealing methods.
Related models and connection choices
Frequently asked questions
6 questions and answers covering size, use, technical checks and quotations.
Can this tee connect to a female-threaded valve?
It may be suitable when thread size and standard match. Check assembly clearance and the load imposed by the valve.
Why check three dimensions for a threaded tee?
It has two pipe connections and one threaded branch. Main-pipe diameter alone is not enough to select the code.
How do I choose the size?
Measure the PE pipe outside diameter in millimetres, then confirm the nominal inch size and thread standard at the metal threaded end. Metal alloy, temperature suitability and pressure rating require the product technical declaration.
How do I verify the pressure and temperature suitability?
Do not assign PN16 to this range based on the name of another series. Provide the product code, fluid, operating temperature and required pressure conditions; confirm suitability with a technical data sheet and written quote.